# Firmware 1.10.13 release notes The following release note provides an overview of the features of the **Firmware 1.10.13** version. The firmware update file for the OVP81x devices is available on [ifm.com](https://www.ifm.com). ## Compatibility ### Previous releases The previous version is v1.4.30. ### Compatible software versions This firmware release works with the following software package versions. | Software | Version | | ------------------------ | -------- | | ifmVisionAssistant | >= 2.9.9 | | ifm3d library | >= 1.5.3 | | ifm3d-ros ROS(1) wrapper | >= 1.1.2 | | ifm3d-ros2 ROS2 wrapper | >= 1.2.0 | ### Compatible processing platforms :::{warning} FW 1.10.13 does not support the OVP80x family at the moment. **Do not update an OVP80x with this firmware. Such a FW update will fail, and the device will reboot to the previous FW version installed.** ::: This firmware release can be applied to the following ifm video processing platforms: | Article | Description | | ------- | --------------------------------------------------------------------------- | | OVP810 | Series product with TX2-NX NVIDIA board. | | OVP811 | Series product with TX2-NX NVIDIA board, including an ODS license. | | OVP812 | Series product with TX2-NX NVIDIA board, including a PDS license. | | OVP813 | Series product with TX2-NX NVIDIA board, including ODS and PDS licenses. | ### Supported camera articles This firmware release supports the following ifm camera articles: | Camera Article | Description | | -------------- | ----------------------------------------------------------- | | O3R222 | 3D: 38k 224x172, 60°x45° IP54
2D: 1280x800, 127°x80° | | O3R225 | 3D: 38k 224x172, 105°x78° IP54
2D: 1280x800, 127°x80° | ## Base device ### Changed - The default `channelValue` for 3D port number X [0..5] is changed to 2*X. - The L4T kernel version is updated to r32.7.5. ## ODS application ### Added - **Diagnostics for decalibrated camera ports:** A new error, `ERROR_ODSAPP_CAMERA_DECALIBRATED`, is raised if any active camera port is likely to be decalibrated. In this case, the camera calibration should be verified. - A new parameter, `rangeOfInterest`, allows users to define the maximum range of vision in meters (in robot coordinates). This setting directly impacts the grid shape, which is always square with each dimension containing (`rangeOfInterest`/0.05) × 2 cells at the default resolution of 5 cm. - ODS supports polygons on the zone interface, allowing for the definition of both convex and concave shapes. - A preset feature is implemented where the user can load a predefined zone configuration. ### Changed - The maximum number of points to define a zone is increased from 6 to 16. - The ODS diagnosis sources are now attached to the specific camera port rather than the overall ODS application, for the following diagnostic messages: - `ERROR_ODSAPP_FOV_INSUFFICIENT_FOR_NEGATIVE_OBSTACLES` - `ERROR_ODSAPP_CAMERA_DECALIBRATED` - `ERROR_ODSAPP_EXTR_DI_CALIB_IMPLAUSIBLE` - `ERROR_ODSAPP_VO_EXTR_DI_CALIB_IMPLAUSIBLE` - A maximum of one ODS instance is allowed. It is expected to use a single ODS application, which is always in `RUN` mode, and to switch the `activePorts` to change which cameras are used. - The conditions for raising the `ERROR_ODSAPP_VO_EXTR_DI_CALIB_IMPLAUSIBLE` diagnostic message were relaxed. ### Known issues - The diagnostics activated by the ODS application during the `RUN` state will not be deactivated when the application is set to the `CONF` or `IDLE` state. - If the negative obstacle feature is enabled, it may happen that the diagnostic message `ERROR_ODSAPP_FOV_INSUFFICIENT_FOR_NEGATIVE_OBSTACLES` is raised even thought the field of view conditions are fulfilled. In this case, negative obstacles will not be properly detected. To fix this, the application should be set to `CONF`, and then to `RUN` again. ## PDS application - A new Pick and Drop System (PDS) application is added. This is a new feature with firmware 1.10.13. Refer to [the PDS documentation](../../../PDS/index_pds.md) for an overview of the available features.